Search
TPI 709R Flue Gas Analyser
TPI 709R Flue Gas Analyser

TPI 709R Flue Gas Analyser

£357.00 ex. VAT
£428.40 inc. VAT
RRP: £504.00
Information

The TPI 709R Flue Gas Combustion Efficiency Analyser includes all the features you’ll need for Boiler commissioning, service and maintenance including performing Flow & Return and Tightness Tests.

Compare & Save with the Easy-To-Use, TPI 709R Flue Gas Combustion Efficiency Analyser designed to measure CO, O2, Temperature & Pressure and calculate CO2 (in a flue), CO/CO2 ratio, efficiency and excess air.

With a large, easy-to-read, backlit display, simple to navigate operating system at a Low Starting Price of JUST £360.00 with Fixed Price Annual Servicing at £85.00, it really is the most cost efficient FGA on the market.

The standard kit comes complete with the 709R in a protective rubber boot, temperature sampling probe c/w external large water trap and unique in-lid water trap (as used by British Gas), soft carry case with shoulder strap, rechargeable battery pack & charger, pressure adaptors, ambient air probe, spare particle filter and instruction manual.

  • Various other kits available including IR Printer, Temperature Pipe Clamps, CPA1 Probes & Gas Leak Detector
  • Print “Live” or “Stored” readings to optional A740 IR Printer
  • Six Year Warranty: Long Life O2 & CO sensors meaning lower servicing costs during a 6 Year Warranty Period*. Saving TIME & MONEY in cost of ownership during annual servicing!

TPI 709R Features

  • Measure CO, O2 & Flue Temperature
  • Calculate CO2, CO/CO2 Ratio, Efficiency & Excess Air
  • Dual Input Differential Manometer – Great for performing Standing Pressure or Let By/Tightness Tests
  • Dual Input Differential Thermometer – Ideal for measuring & recording Flow & Return Temperatures
  • Ambient CO Analysis
  • 6 Year Warranty* (* subject to annual service being carried out each year by TPI or one of its approved local service centres)
  • Diagnostic software & technical helpline combine to save time and money on reduced downtime as many of the reported faults can be rectified over the phone keeping you and your instrument working
  • Unique external water trap filtration system as standard on all kit options preventing loss of downtime or additional costs due to potentially damaged sensors caused by water ingress
  • 10 Fuel options including Wood, Light & Heavy Oil, LPG and Natural Gas
  • Will not shut off if CO ppm is above 15ppm for increased safety for both the user and the instrument
  • Unique in-line pump protection filter fitted as standard across all kits preventing loss of downtime or additional costs due to a potentially damaged pump caused by dust/dirt ingress
  • Protective rubber boot as standard to protect the FGA
  • Re-Chargeable battery housed in a separate compartment ensuring no heat transfer when using on the mains to affect gas readings
  • All kits come supplied in a soft carry case to protect not only the FGA but all of your accessories
  • Capability of sending Live or Stored readings to an optional IR Printer
Model 709R Specifications
 Instrument
 Operating Temperature Range  14°F to +122°F (-10°C to +50°C)
 Battery / Batery Life  Rechargeable Ni-MH / > 6 Hours
 Charger Input Voltage  115V or 230V : 50/60 Hz AC
 Fuels  Natural Gas, LPG, Light Oil, Heavy
Oil, Bituminous Coal,
Anthracite
Coal, Coke, Butane, Wood, Bagasse
 Pressure Ranges  mbar, kPa & inH2O
 Display  Backlit Graphic LCD
 Data Storage  50 sets of readings, multiple pages
 Time and Date  24 Hour Real Time Clock
 Dimensions  7.8” (200mm) x 3.5” (90mm) x 2.4” (60mm)
 Weight  500g
 Casing  Rubber Boot as Standard
 Switch Off  Failsafe
 Exhaust  Safety Spigot
 Conforms to  EN50379

 Flue Temperature Probe
 Construction  Pistol Grip with Stainless Steel Shaft
 Hose Length  8.2’ (2500mm)
 Insertion Length  7.9” (200mm)
 ‘K’ Type Thermocouple Accuracy  +/- 0.3% of fullscale, +/- 2°F (1°C)
 Maximum Temperature  1472°F (800°C)

 Gases  Range  Resolution  Accuracy
 Oxygen  0-25%  0.1%  +/- 0.3%
 Carbon Monoxide  0-10,000 ppm  1 ppm  (<20ppm) +/- 3 ppm
(>=100ppm) +/- 5%
 Carbon Dioxide (calculated  0-25%  0.1%  Calculated
 CO/CO2 Ratio  0-0.999  0.001  +/- 0.3%
 Combustion Efficiency  0-100%  0.1%

 Pressure Measurement
 Selectable Ranges  mbar, kPa and inH2O
 Range  – 150 mbar to + 150 mbar
 Resolution  0.01 mbar & 0.1 mbar

709R Kit with Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual

709R Kit 1 With Standard Accessories and includes:

Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer

709R Kit 2 With Standard Accessories and includes:

Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer
  • 2 x CK21M Pipe Clamps

709R Kit 3 With Standard Accessories and includes:
Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer
  • 2 x CK21M Pipe Clamps
  • CPA1 Probe Kit

709R Kit 4 With Standard Accessories and includes:
Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer
  • 2 x CK21M Pipe Clamps
  • TPI 719 Gas Leak Detector
 

709R Kit 5 With Standard Accessories and includes:

Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer
  • 2 x CK21M Pipe Clamps
  • CPA 1 Probe Kit
  • TPI 719 Gas Leak Detector

709R Kit 1 Oil With Standard Accessories and includes:
Standard Accessories:

  • TPI 709R Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Sampling Probe (c/w Type “K” Thermocouple)
  • In-Line Water Trap Bowl Filter (c/w Spare Particle Filter)
  • Battery Charger (A766)
  • Mini In-Line Pump Protection Filter (A763) (c/w 5 spare filters)
  • Exhaust Spigot Removable (A764)
  • Pressure Tubing (2 x 1 metres)
  • GK11M Air Probe
  • Instruction Manual
  • A740 Infra-Red Printer
  • Smoke Pump
  • Oil Filter

 Click here for the TPI 709R Data Sheet    Click here for the TPI 709R User Manual