Search
TPI 716 Flue Gas Analyser with NOx
TPI 716 Flue Gas Analyser with NOx

TPI 716 Flue Gas Analyser with NOx

£724.00
£868.80 (inc. VAT)
£805.00 inc VAT
Information

The TPI Model 716 Flue Gas Analyser is a state of the art, easy to use Analyser designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion across a wide range of fuels including Oil & Wood as well as the more standard Natural Gas & LPG.

The Feature Rich, but still Easy-To-Use, TPI 716 Deluxe Flue Gas Combustion Efficiency Analyser is designed to meet the needs of the busiest Gas Heating Engineer and Installer.

Compare & Save with the TPI 716 Flue Gas Analyser. All the great features of the TPI 709R including the same Low Cost Annual Servicing from £85.00 PLUS the ability to take & record a Timed Let By/Tightness Test and Timed CO Build Up Test using new Menu Driven Interface which also allows for super quick start-up by eliminating the need to perform an initial purge period.

The 716 has a large capacity pump with visible flow rate on screen and a Calibration Due Countdown amongst many other great features!

Starting at just £525.00 with USB connectivity & PC software as standard and the ability to upgrade NOW or LATER to have such features as NO/NOx, High CO, Plug-In Leak Sniffer or Bluetooth the TPI 716 really is the only piece of kit you’ll need no matter what the job entails.

  • Various other kits available including IR Printer, Temperature Pipe Clamps, CPA1 Probes & Gas Leak Detector
  • Print “Live” or “Stored” readings to optional A740 IR Printer
  • Six Year Warranty: Long Life O2 & CO sensors meaning lower servicing costs during a 6 Year Warranty Period*. Saving TIME & MONEY in cost of ownership during annual servicing!

The TPI 716 conforms to EN50379 and is suitable for engineers working with BS7967, the usage standard.

Serial Number & Next Cal Due Date are printed at the bottom of each print-out ensuring that you always know your readings have been taken with the correct in-calibration flue gas analyser giving you complete peace of mind.

HHIC: The Heating & Hot water Industry Council made a recommendation that from April 2013 that the CO level & CO/CO2 (Ratio) reading in a flue is recorded when a boiler is commissioned and that this practise become mandatory from April 2014. Please click here for further details.

The recording of the CO level and Ratio reading will become a mandatory part of completing the Benchmark Form.

Model 716 Specifications
 Instrument
 Operating Temperature Range  14°F to +122°F (-10°C to +50°C)
 Battery / Batery Life  Rechargeable Ni-MH / > 6 Hours
 Charger Input Voltage  115V or 230V : 50/60 Hz AC
 Fuels  Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
 Pressure Ranges  mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
 Display  Backlit Graphic LCD
 Data Storage  100 sets of readings, multiple pages
 Time and Date  24 Hour Real Time Clock
 Dimensions  7.8” (200mm) x 3.5” (90mm) x 2.4” (60mm)
 Weight  1.1lbs (500g)
 Conforms to  EN50379

 Flue Temperature Probe
 Construction  Pistol Grip with Stainless Steel Shaft
 Hose Length  8.2’ (2500mm)
 Insertion Length  7.9” (200mm)
 ‘K’ Type Thermocouple Accuracy  +/- 0.3% of fullscale, +/- 2°F (1°C)
 Maximum Temperature  1472°F (800°C)

 Gases  Range  Resolution  Accuracy
 Oxygen  0-25%  0.1%  +/- 0.3%
 Carbon Monoxide (low)  0-10,000 ppm  1 ppm  (<100ppm) +/- 5 ppm (>=100ppm) +/- 5%
 Carbon Monoxide (high)  0-100,000 ppm  0.001%  >10,000ppm: +/- 10%
 Nitric Oxide *  0-5000ppm  1 ppm  +/- 5ppm (<100ppm) +/- 5% (<1000ppm) +/- 10% (>1000ppm)
 Carbon Dioxide  0-25%  0.1%  Calculated
 CO/CO2 Ratio  0-0.999  0.001  Calculated
 Combustion Efficiency  0-100%  0.1%  Calculated
 Gas Leak Sensor  100-10,000ppm (calibrated to methane)

* if fitted

 Pressure Measurement
 Selectable Ranges  mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
 Range  – 100 mbar to + 100 mbar -10 kPa to + 10 kPa -40 inH2O to 40 inH2O
 Resolution  0.001 mbar (0~9.999 mbar) 0.01 mbar (10.00~99.99 mbar)
 Accuracy  < 5 mbar: +/- 0.05 mbar > 5 mbar: +/- 1% of reading

 Temperature Measurement
 Input Type  K-Type thermocouple
 Range  -58°F to 2372°F (-50°C to 1300°C)*
 Resolution  1°F (1°C)
 Accuracy  +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)
 

716 Kit With Standard Accessories:

  • TPI 716 Analyser
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Flue Sampling Probe (A770) – 1 each
  • In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
  • Disc water filter installed in water trap (A796W) – 1 each
  • Spare In-Line Filter – 1 each (A796F is a package of 10 filters)
  • Temperature Probe (GK11M) – 1 each
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Adapters – Pair (A772) 1 pair
  • PC Software and cable for communication to a PC (A807).
  • Instruction Manual

716 Kit 1 With Standard Accessories and includes:
A740 Infra-Red Printer

  • TPI 716 Analyser with NO Sensor fitted
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Flue Sampling Probe (A770) – 1 each
  • In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
  • Disc water filter installed in water trap (A796W) – 1 each
  • Spare In-Line Filter – 1 each (A796F is a package of 10 filters)
  • Temperature Probe (GK11M) – 1 each
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Adapters – Pair (A772) 1 pair
  • PC Software and cable for communication to a PC (A807).
  • Instruction Manual

716 Kit 2 With Standard Accessories and includes:
A740 Infra-Red Printer
2 x CK21M Pipe Clamps

  • TPI 716 Analyser with NO Sensor fitted
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Flue Sampling Probe (A770) – 1 each
  • In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
  • Disc water filter installed in water trap (A796W) – 1 each
  • Spare In-Line Filter – 1 each (A796F is a package of 10 filters)
  • Temperature Probe (GK11M) – 1 each
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Adapters – Pair (A772) 1 pair
  • PC Software and cable for communication to a PC (A807).
  • Instruction Manual

716 Kit 4 With Standard Accessories and includes:
A740 Infra-Red Printer
2 x CK21M Pipe Clamps
716 Plug In Gas Leak Sniffer

  • TPI 716 Analyser with NO Sensor fitted
  • Rubber Boot (A765) 1 each installed on analyser
  • Soft Carrying Case (A768) – 1 each
  • Flue Sampling Probe (A770) – 1 each
  • In-Line Filter / Water Trap installed on Flue probe (A796) – 1 each
  • Disc water filter installed in water trap (A796W) – 1 each
  • Spare In-Line Filter – 1 each (A796F is a package of 10 filters)
  • Temperature Probe (GK11M) – 1 each
  • Battery Charger (A766) – 1 each
  • Mini Pump Protection Filter Assembly (A763) – 1 each
  • Exhaust Spigot Removable (A764) – 1 each
  • Pressure Adapters – Pair (A772) 1 pair
  • PC Software and cable for communication to a PC (A807).
  • Instruction Manual

 Click here for the TPI 716 Data Sheet    Click here for the TPI 716 User Manual